Current Clamp Meter Current Terminal Meter Leakage Current Measurement DC/AC Current Measurement Digital Clamp Meter ETCR6300

Availability: 0
ID: 568850
Product Code: ANEB0F3CN17DGT

244.26€
(Ex Tax: 201.87€)

Delivery by

DPD delivery Omniva delivery Smartpost delivery FedEx delivery Venipak delivery 

Payment options

Pay with Swedbank Pay with Apple Pay Pay with Google Pay Pay with Visa Pay with Mastercard 


Description
High precision technology, high measurement accuracy, strong reliability and bandwidth response frequency It is particularly suitable for current test in places with stretchable cables, the core current test of transformers connected to the subway to the subway, thick testing wires and cables, relay protection, electronic energy conversion equipment, arc welding and other industrial environments where the signal is highly distorted. Precision wound terminal head, highlighting high precision Specially designed and manufactured for online testing, monitoring, monitoring and recording AC and large current Its small size, light weight, exquisite appearance, soft and flexible, suitable for tight environments and places with stretchy cables › See more product details; Product description The ETCR6300. Trapping current meter is specially designed and manufactured to measure AC injury current. It adopts CT technology and digital integration technology and has the features of small size, high precision and full functions. It is widely used in electrical energy, communication, meteorology, railways, oil fields, construction, measurement, scientific research and teaching units. industrial and mining companies and other fields. The sensor core is made of special alloys and magnetic shielding technology, which is almost unaffected by the external magnetic field to ensure high precision, high stability and high reliability for year-round continuous measurement. The instrument has an RS232 interface, its software can be online real-time monitoring and historical query, dynamic display. There are maximum, minimal, average displays with alarm value setting and alarm display functions with historical data reading, memory, printing and other functions Specification: Function: AC current measurement, AC current measurement, online AC current measurement Measuring range: 0.001ma-60.00A. Resolution: 1UA. Measuring accuracy: 23 ℃ ± 3 ℃, below 70% RH, ± 1.5% ± 5 dgt Power source: alkaline dry battery 6LR61 9V, continuous work for about 80 hours. Meter weight: 210 g (including battery). Instrument size: height, width and thickness: approx. 175 mm x 70 mm x 38 mm. Jaw size: 25 mm × 30 mm. LCD size: 35 mm x 21.5 mm; display range: 32 mm x 15 mm. Sampling rate: approx. 2 times/s. Display mode: 4-digit LCD display. Test Method: Clamp CT, Integral Method Frequency: 50 Hz, 60 Hz automatic detection. Communication interface: RS232 interface, memory data can be uploaded to the computer, software monitoring Data storage: 99 groups, flashing \; Product description The ETCR6300. Trapping current meter is specially designed and manufactured to measure AC injury current. It adopts CT technology and digital integration technology and has the features of small size, high precision and full functions. It is widely used in electrical energy, communication, meteorology, railways, oil fields, construction, measurement, scientific research and teaching units. industrial and mining companies and other fields. The sensor core is made of special alloys and magnetic shielding technology, which is almost unaffected by the external magnetic field to ensure high precision, high stability and high reliability for year-round continuous measurement. The instrument has an RS232 interface, its software can be online real-time monitoring and historical query, dynamic display. There are maximum, minimal, average displays with alarm value setting and alarm display functions with historical data reading, memory, printing and other functions Specification: Function: AC current measurement, AC current measurement, online AC current measurement Measuring range: 0.001ma-60.00A. Resolution: 1UA. Measuring accuracy: 23 ℃ ± 3 ℃, below 70% RH, ± 1.5% ± 5 dgt Power source: alkaline dry battery 6LR61 9V, continuous work for about 80 hours. Meter weight: 210 g (including battery). Instrument size: height, width and thickness: approx. 175 mm x 70 mm x 38 mm. Jaw size: 25 mm × 30 mm. LCD size: 35 mm x 21.5 mm; display range: 32 mm x 15 mm. Sampling rate: approx. 2 times/s. Display mode: 4-digit LCD display. Test Method: Clamp CT, Integral Method Frequency: 50 Hz, 60 Hz automatic detection. Communication interface: RS232 interface, memory data can be uploaded to the computer, software monitoring Data storage: 99 groups, flashing \; The ETCR6300. Trapping current meter is specially designed and manufactured to measure AC injury current. It adopts CT technology and digital integration technology and has the features of small size, high precision and full functions. It is widely used in electrical energy, communication, meteorology, railways, oil fields, construction, measurement, scientific research and teaching units. industrial and mining companies and other fields. The sensor core is made of special alloys and magnetic shielding technology, which is almost unaffected by the external magnetic field to ensure high precision, high stability and high reliability for year-round continuous measurement. The instrument has an RS232 interface, its software can be online real-time monitoring and historical query, dynamic display. There are maximum, minimal, average displays with alarm value setting and alarm display functions with historical data reading, memory, printing and other functions Specification: Function: AC current measurement, AC current measurement, online AC current measurement Measuring range: 0.001ma-60.00A. Resolution: 1UA. Measuring accuracy: 23 ℃ ± 3 ℃, below 70% RH, ± 1.5% ± 5 dgt Power source: alkaline dry battery 6LR61 9V, continuous work for about 80 hours. Meter weight: 210 g (including battery). Instrument size: height, width and thickness: approx. 175 mm x 70 mm x 38 mm. Jaw size: 25 mm × 30 mm. LCD size: 35 mm x 21.5 mm; display range: 32 mm x 15 mm. Sampling rate: approx. 2 times/s. Display mode: 4-digit LCD display. Test Method: Clamp CT, Integral Method Frequency: 50 Hz, 60 Hz automatic detection. Communication interface: RS232 interface, memory data can be uploaded to the computer, software monitoring Data storage: 99 groups, flashing \
The color of the product shown on the display may differ from the actual one. The product description is general and may not necessarily reflect all specific technical features of the product. Prices in the online store may differ from prices in physical stores and service centers. Warehouse stock in the store and in the online shop may vary, therefore in certain cases the delivery time may differ from the one indicated at the moment of order and/or the order may not be fulfilled in full (in such a case, the customer will be informed in advance). 

Product compliance check: if the order is placed for a legally regulated product (e.g., a restricted or licensed item), JusuPrekes.lt reserves the right to decline the order after assessing its legal compliance.

Spotted a mistake? Report it to us

ESTO leasing Jusuprekes.lt – simple and fast buy now, pay later option